Raymax offers a wide range of home UPS systems to keep your appliances functioning smoothly during power failures. Every Raymax Home UPS system is 100% reliable and are manufactured with the latest technology and can be customized according to your requirements.
Raymax home UPS device has been designed as a complete package to provide superior performance and reliability. It is compact and lighter than any other UPS in its class. It is ergonomically designed to give the best operating environment for critical components to offer ultimate reliability with good aesthetics.
Connection Type | Single Phase |
Battery input voltage | 12V |
Mains input voltage | 230V AC, 50Hz |
Mains input range | 0V-270V, 45Hz to 65Hz |
Mains high voltage withstand | Up to 440V |
AC output (Inverter) | 50/60Hz |
Battery full Cut-of | 14.2V |
Inverter output waveform | Pure sine wave (harmonic distortion less than 1%) |
Inverter topology | Bridge type center aligned switching MOSFET based |
Inverter output power | 950VA |
Battery charging voltage | Intelligent 4 stage charger constant current/constant voltage SMPS charging with full charge cut off. |
Charging current | Settable from 1A to 15A |
Charging working range | 120V-270V AC Mains input |
Inverter high cut-off voltage | 270v |
Inverter low cut-off voltage | 100v |
UPS high cut-off voltage | 265v |
UPS low cut-off voltage | 180v |
Battery low warning | 10.5v |
Battery low cut-off | 10V |
Operating temperature | 00C TO 550C |
Cooling fan auto-ON temp | 700C |
Cooling fan auto-OFF temp | 600C |
Storage temperature | -150C TO 600C |
Humidity | 5% to 95% Relative humidity (Non-condensing) |
Inverter protection | Overload, short circuit, battery deep discharging |
Connection Type | Single Phase |
Battery input voltage | 12V DC- 48V DC (Various models) |
Mains input voltage | 230V AC, 50Hz |
Mains input range | 0V-270V, 45Hz to 65Hz |
Mains high voltage withstand | Up to 440V |
AC output (Inverter) | 230V ± 3%, 50Hz |
Battery full Cut-of | 14.5V |
Inverter output waveform | Pure sine wave (harmonic distortion less than 1%) |
Inverter topology | Bridge type center aligned switching MOSFET based |
Inverter output power | 1650 VA, 2000 VA, 2500 VA, 3000 VA |
Battery charging voltage | Intelligent 4 stage charger constant current/constant voltage SMPS charging with full charge cut off. |
Charging current | Settable from 1A to 15A |
Charging working range | 120V-270V AC Mains input |
Inverter high cut-off voltage | 270v |
Inverter low cut-off voltage | 100v |
UPS high cut-off voltage | 265v |
UPS low cut-off voltage | 180v |
Battery low warning | 10.5v |
Battery low cut-off | 10V |
Operating temperature | 00C TO 550C |
Cooling fan auto-ON temp | 700C |
Cooling fan auto-OFF temp | 600C |
Storage temperature | -150C TO 600C |
Humidity | 5% to 95% Relative humidity (Non-condensing) |
Inverter protection | Overload, short circuit, battery deep discharging |
Specification | Inverter Mode | UPS Mode |
---|---|---|
Input voltage Range | 100V – 270V ± 10V | 180V – 265V ± 10V |
Changeover time (Inverter to mains) | Approx<=10msec | Approx<=10msec |
Changeover time (Mains to Inverter) | Approx<=40msec | Approx<=30msec |